Skip to main content
Home / Products / Cooling Water Chemical / CorroShield L05 Corrosion Inhibitor
IMPA / ISSA CERTIFIED MARINE PRODUCT

CorroShield L05 Corrosion Inhibitor

Cooling Water Chemical CorroShield L05 Corrosion Inhibitor
Express Mormugao Port 2-4 Hr Berth Delivery
Cooling Water Chemical
IMPA / SKU Code: RXSOL-43-4018-028

RXSOL-43-4018 is a superior molybdate based corrosion inhibitor developed for use in closed cooling water systems. RXSOL-40-4018 prevents corrosion and deposits in closed and aerated cooling water systems.

Available Packaging:
Corrosion inhibitor closed cooling systems Molybdate Phosphonate available in 30 Kg Ltr, 50 Ltr, 220 Ltr pack.
Ready Port Stock 25L, 210L Drums & 1000L IBC
IMPA / ISSA Standard MARPOL Compliant Formulations
ISO 9001:2015 QA TDS, MSDS & COA Available

Application & Uses

CorroShield L05 Corrosion Inhibitor Molybdate is mainly applied in secondary cooling water systems of Power Plants, in the cooling systems of blast furnaces, in systems for cooling the molds in continuous casting mills and in hot and cold water systems in the chemical industry. The program should be used with soft water, to avoid calcium phosphate deposition when the water losses are important.

 

Ingredient: Metal Pretreatment Filming Agent, Film Settlement Agent, Surface Activating Agent, Sodium Molybdate, Organophosphorus etc.                                                                               

Corrosion Rate             : ≤0.125mm / year (Steel)                                                   
Scale Formation Rate  : ≤0.2mm / year

Dosage & Directions for Use

CorroShield L05 Corrosion Inhibitor is added neat or diluted to the cooling water. CorroShield L05 Corrosion Inhibitor can be mixed with water in any ratio.

Dosage requirements - The dosage rate is dependent on the system conditions and the amount of water lost from the system.

RXSOL CorroShield L05 should be applied at a dosage of 1% by volume (10 litres per m³) to achieve a reserve of 400-600 ppm sodium molybdate (equivalent to 310-450 ppm molybdate as MoO₄) and 400-600 ppm sodium nitrite (equivalent to 270-400 ppm nitrite as NO₂).

If the system pH is higher than 8, it may be necessary to adjust the pH separately by using a suitable pH conditioner; your RXSOL representative can provide guidance on this.

Where significant system passivation is required, a higher initial dosage may be needed in order to obtain the required inhibitor residual levels.

Where necessary, a biocide should also be applied, such as RXSOL MICRO BIOCIDE (RXSOL-40-4009-025).

Note: For all systems containing aluminium, it is essential to maintain the pH within the range of 7–8. Dosage levels for aluminium systems are also higher.

 

For RXSOL Corrosion Inhibitor Molybdate Phosphonate (RXSOL-40-4018-025) below dosage article must be followed:

Systems should maintain 400 ppm - 1000ppm of product in the water, while systems with high water losses should maintain ca. 1500 ppm in the system.

For further technical assistance please contact RX MARINE TECH DEPT.

DOSAGE: Corrosion inhibitor closed cooling systems Molybdate Phosphonate dosages may vary somewhat according to operating conditions, but generally 400-1000 ppm of Corrosion inhibitor closed cooling systems Molybdate Phosphonate should be maintained in the system water. This dosage should be doubled for a two-week period when initiating treatment, whenever the system is refilled with fresh water, and after any major system upsets, in order to establish effective corrosion control. If the stability index of the recirculated water is higher than 10.5, an alkalinity booster such as RXSOL pH Booster should be fed to reduce the index to less than 10.5.

Corrosion inhibitor closed cooling systems Molybdate Phosphonate should not be used when the stability index of the system water is below 3.0.

Corrosion inhibitor closed cooling systems Molybdate Phosphonate is controlled by a molybdate test, which provides easy and accurate control readings. Maintain 1 to 5 ppm MoO4 = at all times.

FEEDING: Corrosion inhibitor closed cooling systems Molybdate Phosphonate must be fed continuously to the system by a positive displacement chemical feeder. For maximum results, feed should be linked to makeup of bleedoff through the use of a flowmeter or conductivity controller. Residuals are adjusted and maintained by chemical test of the system to provide a residual of 1-5 ppm MoO4 = .

HANDLING: Avoid contact with skin and eyes. Wear suitable protective equipment (refer to MSDS for further information).

Technical Specifications & Properties

RXSOL L05 Corrosion Inhibitor Closed Circulation Machinery Cooling Corrosion inhibitor.

Appearance

Clear Colourless to Pale Liquid

Boiling point [oC]

100

C Density [kg/m3]

1.12 - 1.20

Flashpoint[oC] TCC

NONE Vapour pressure [mm Hg]

Pour point [oC]

NONE Vapour density [a ir=1]:

Auto-ignition temp [oC] NONE 
Expl.omr. [vol%] Solubility in water [w-%]: 100%
pH : Slight Alkaline
Solubility  100% in Distilled water

Product Description & Chemical Profile

Molybdate and phosphonate based corrosion inhibitor for cooling water system. We are manufacturer and supplier of this special type of corrosion inhibitor which acts as Filming Agent to protect metal surface from corrosion and its chemical reaction also help to prevent formation of calcium phosphate deposition.

This corrosion inhibitor is specifically formulated for the protection of closed-loop systems, including closed chilled-water circuits and low-pressure heating systems.

CorroShield L05 is based on a balanced blend of organic and inorganic corrosion inhibitors and has proven performance in protecting steel, copper, aluminium and other non-ferrous metals.

RXSOL L05 is a high-efficiency corrosion-inhibitor formulation designed to provide reliable and long-term protection for closed chilled-water and low-pressure heating systems.

Mormugao Port Logistics Desk

Need pricing, bulk volume, or vessel delivery today?

Send us your required quantity, delivery location, or vessel IMO number. Our technical marine supply team replies within 1 hour.