Cooling Water Corrosion and Deposit Inhibitor
RXSOL Cooling Water Corrosion and Deposit Inhibitor is a specially formulated liquid water treatment chemical designed to provide combined corrosion inhibition, scale control and deposit management in industrial cooling water systems.
Application & Uses
Major Applications
Cooling Towers: Used in open recirculating cooling water systems to control corrosion and mineral scale.
Heat Exchangers: Helps reduce mineral deposits on compatible heat-transfer surfaces.
Industrial Cooling Circuits: Supports corrosion and deposit control in process cooling systems.
Condensers: Helps minimize scaling and corrosion in compatible cooling water condensers.
Power Plants: Used as part of cooling water treatment programmes for suitable power generation cooling circuits.
Petrochemical and Refinery Cooling Systems: Supports corrosion and scale management in industrial cooling water networks.
HVAC Cooling Systems: Suitable for selected central air-conditioning cooling tower applications.
Manufacturing Facilities: Used in cooling water circuits serving chemical plants, steel processing, plastics, textile and other industrial operations.
Dosage & Directions for Use
Recommended Dosage
The required dosage depends on circulating water quality, hardness, alkalinity, chloride concentration, operating pH, cycles of concentration and system metallurgy.
For preliminary treatment planning, an illustrative range for some formulated cooling water inhibitors is:
|
Application |
Illustrative Treatment Range |
|---|---|
|
Open Cooling Tower System |
30–100 ppm product in circulating water |
|
Moderate Hardness Cooling Water |
50–100 ppm product |
|
High Hardness Cooling Water |
Determined by water analysis |
|
Initial System Treatment |
Calculated from system volume and target residual |
|
Continuous Treatment |
Adjusted for blowdown and chemical losses |
Important: These are general industry screening ranges, not validated dosing instructions for this specific RXSOL product. A final dosage must be established from the actual formulation and site water analysis.
Technical Specifications & Properties
Typical Physical & Chemical Properties
|
Property |
Typical Description |
|---|---|
|
Product Name |
Cooling Water Corrosion and Deposit Inhibitor |
|
Brand |
RXSOL |
|
Appearance |
Liquid |
|
Colour |
Formulation-dependent |
|
Chemical Nature |
Corrosion inhibitor and scale/deposit control formulation |
|
Solubility |
Water-compatible formulation |
|
pH |
To be confirmed from finished product specification |
|
Specific Gravity |
To be confirmed from finished product specification |
|
Corrosion Control |
For compatible cooling system metals |
|
Scale Control |
Calcium carbonate and other susceptible mineral deposits |
|
Application |
Open recirculating cooling water systems |
|
Dosing Method |
Continuous or controlled dosing |
|
Compatibility |
Depends on system metallurgy and water chemistry |
The above table describes the intended product characteristics. Exact analytical specifications must be confirmed from the approved RXSOL formulation and batch quality-control results.
Recommended Industrial & Shipboard Areas
Frequently Asked Questions
Q1. What is RXSOL Cooling Water Corrosion and Deposit Inhibitor used for?
It is intended to control corrosion, mineral scale and deposits in compatible industrial cooling water systems.
Q2. Can the product be used in cooling towers?
Yes, it is intended for selected open recirculating cooling tower applications.
Q3. Does the product prevent calcium carbonate scale?
A suitable inhibitor formulation can reduce calcium carbonate precipitation and deposition within its validated operating range.
Q4. Can it protect carbon steel and copper alloys?
Carbon steel corrosion inhibition is a principal application. Copper alloys may require additional corrosion inhibitor chemistry, such as azoles.
Q5. Can it be used in closed chilled water systems?
Not automatically. Closed chilled water systems generally require a different treatment strategy and may require a dedicated closed-loop corrosion inhibitor.
Q6. How frequently should the product be dosed?
Continuous dosing is commonly used in open recirculating systems, with the feed rate adjusted according to blowdown losses and monitored inhibitor residual.
Q7. Does this product replace biocides?
No. Corrosion and scale inhibitors do not necessarily provide microbiological control. A separate biocide programme may be required.
Product Description & Chemical Profile
It is designed for use in systems with recirculating water calcium concentrations between 50 and 1000 ppm (as CaCO3) at the targeted cycles when the pH is less than.This product is designed for Alkaline waters.
PRODUCT BULLETIN
RXSOL COOLING WATER CORROSION AND DEPOSIT INHIBITOR
Product Name: Cooling Water Corrosion and Deposit Inhibitor Brand: RXSOL Product Category: Industrial Water Treatment Chemicals Application: Cooling Towers, Industrial Cooling Water Systems, Heat Exchangers and Recirculating Water Circuits
Product Description
RXSOL Cooling Water Corrosion and Deposit Inhibitor is a specially formulated liquid water treatment chemical designed to provide combined corrosion inhibition, scale control and deposit management in industrial cooling water systems.
Cooling water systems are continuously exposed to dissolved minerals, oxygen, suspended solids and varying operating temperatures. These conditions can lead to corrosion, mineral scale formation and deposit accumulation on heat-transfer surfaces, pipelines and equipment.
RXSOL Cooling Water Corrosion and Deposit Inhibitor is designed to address these problems through a balanced treatment programme that helps protect compatible metallic surfaces while controlling the precipitation and accumulation of scale-forming minerals.
The product is suitable for use in open recirculating cooling towers and compatible industrial cooling water circuits, subject to water quality, system metallurgy and operating conditions.
Need pricing, bulk volume, or vessel delivery today?
Send us your required quantity, delivery location, or vessel IMO number. Our technical marine supply team replies within 1 hour.