Alkalinity Control
Alkalinity Builder Very usefull Concentrated Alkaline Liquid For Maintaining Ph which protects corrosion, scalling by controlling Calcium scale in water system.
Application & Uses
Applications
1. Marine Boiler Water Treatment
RXSOL Alkalinity Control is intended for maintaining suitable boiler water alkalinity in marine auxiliary boilers and other approved shipboard steam-generating systems.
2. Industrial Steam Boilers
Used in boiler treatment programs for industrial plants, manufacturing facilities and process steam applications.
3. Boiler Water pH Adjustment
Helps correct insufficient boiler water alkalinity, according to water analysis and the boiler manufacturer's recommended control limits.
4. Boiler Corrosion Control
Supports corrosion management by maintaining suitable alkaline conditions on internal boiler surfaces.
5. Phosphate Boiler Treatment Programs
Can be used alongside compatible phosphate-based boiler treatment chemicals where separate alkalinity adjustment is required.
6. Boiler Water Conditioning
Helps maintain appropriate water chemistry during routine boiler operation, subject to proper monitoring and blowdown control.
RXSOL-50-5002-025 provides the alkaline condition for hardness control to function correctly. Without the correct precipitation and subsequent blow down of hardness salt, scale would form. This would result in restriction in water flow, ineffective heat transfer and local corrosion. The end effect would be an inefficient boiler and ultimately component failure. RXSOL-50-5002-025 also provides the alkaline condition required for corrosion control, by neutralization of acidic gases
Dosage & Directions for Use
For optimum results dose RXSOL-50-5002-025 direct to the boiler with a RXSOL Boiler Water Treatment Dosing unit, or via the bypass pot- feeder installed in the boiler feed line.
Required dosage can be controlled by pH & alkalinity test dosage chart .
1 milliliter of RXSOL-50-5002-025 concentrated alkaline liquid per ton of distilled water provides 0.5 ppm of lkalinity hydrate.
Low-pressure boiler (up to 28 bars)
Add RXSOL-50-002-025 to 5 litre in feed – water, There is no any specific method can be passed through the recalculating or the main feed pipe into the stream or the hot well tank.
High – Pressure Boiler (28 to 60 bars)
Dissolve the desired volume of RXSOL-50-002-025 to 5 ltr of feed – water, which should then be passed into the stream or water drum through the chemical pump.
Note:- It can also be used as a neutralizing agent following acid cleaning with descaling materials ( RXSOL-11-1008--DC descaling Liq / RXSOL-54-1008-SA Safe Acid PWD )
Recommended Dosage and Application
Dosage must be determined from actual boiler water alkalinity, system volume, operating pressure, feedwater quality and the concentration of the supplied RXSOL formulation.
Unlike general-purpose detergents, boiler alkalinity control chemicals should not be dosed using a fixed universal percentage.
General Dosing Procedure
-
Collect a representative boiler water sample using an approved cooled sampling arrangement.
-
Measure boiler water pH, P-alkalinity, M-alkalinity and conductivity.
-
Compare the results with the boiler manufacturer's recommended operating limits.
-
Calculate the required chemical addition based on the alkalinity deficit and product concentration.
-
Introduce the product through an approved chemical dosing system.
-
Allow adequate circulation and mixing.
-
Retest boiler water and adjust dosing gradually.
-
Maintain routine monitoring and appropriate boiler blowdown.
Example: Alkalinity Adjustment Calculation
For a hypothetical boiler containing 10,000 litres of water, assume the treatment program requires an additional 100 mg/L of hydroxide alkalinity expressed as CaCO₃.
The theoretical pure NaOH requirement is:
For a hypothetical 25% w/w sodium hydroxide solution:
This calculation assumes that the entire specified increase is attributable to sodium hydroxide, with no buffering or competing reactions. It is an illustration only, not a recommended field dose. Actual treatment requires analysis of the boiler water chemistry and verified product concentration.
Technical Specifications & Properties
Testing control procedure
- Test water sample from the water boiler as described in the direction of the Alkalinity Test Kit ( p & m Total ) http://www.rxmarine.com/Alkalinity-test-kit
- Determine the present alkalinity value expressed as ppm CaCO3 .
- Desired level of 100-150 ppm as CaCO3.
- A control test for the alkalinity of the water should be conducted after 3- 6 hours from the application.
Technical Specifications
|
Parameter |
Typical / Proposed Specification |
|---|---|
|
Product Name |
RXSOL Alkalinity Control |
|
Appearance |
Clear liquid |
|
Colour |
Colourless to pale yellow |
|
Chemical Base |
Alkaline hydroxide-based formulation |
|
pH (Concentrate) |
Strongly alkaline |
|
Water Solubility |
Miscible with water |
|
Primary Function |
Boiler Water Alkalinity Adjustment |
|
Secondary Function |
Boiler Water pH Control |
|
Application |
Marine and Industrial Boilers |
|
Dosing Method |
Controlled chemical dosing |
|
Packing |
25 L, 210 L and 1,000 L, subject to availability |
These are proposed characteristics of an alkaline boiler treatment formulation. Actual RXSOL specifications, product code, hydroxide concentration, density and packaging must be confirmed from the approved TDS and batch COA.
Recommended Industrial & Shipboard Areas
Frequently Asked Questions
Q1. What is RXSOL Alkalinity Control used for?
It is intended for adjusting and maintaining alkalinity in marine and industrial boiler water systems.
Q2. Why is alkalinity important in boiler water?
Correct alkalinity helps control corrosion and supports stable boiler water treatment chemistry.
Q3. Can low boiler water alkalinity cause corrosion?
Yes. Insufficient alkalinity may increase the risk of acidic corrosion, depending on operating conditions and water chemistry.
Q4. Can excessive alkalinity damage boilers?
Yes. Excessive alkalinity can contribute to foaming, steam carryover and caustic-related damage.
Q5. Is RXSOL Alkalinity Control an oxygen scavenger?
No. Alkalinity adjustment and dissolved oxygen removal are separate treatment functions.
Q6. Can the product be used with phosphate boiler treatment?
It may be used alongside a compatible phosphate treatment program where separate alkalinity adjustment is necessary.
Q7. How much RXSOL Alkalinity Control should be added?
The dose depends on the measured alkalinity deficit, boiler water volume, operating conditions and actual product concentration.
Q8. Is the product suitable for high-pressure boilers?
Suitability depends on the boiler pressure, manufacturer requirements and the verified formulation. High-pressure systems often require more restrictive water chemistry controls.
Q9. What is RXSOL ALCA SOLUTION used for?
It is intended to raise and maintain boiler water alkalinity and pH.
Q10. Can it prevent boiler corrosion?
Maintaining proper alkalinity helps reduce corrosion caused by acidic boiler water, but complete corrosion control also requires appropriate oxygen control and overall water chemistry management.
Q11. Can it be used with oxygen scavengers?
It may be incorporated into a boiler treatment programme containing a compatible oxygen scavenger. Concentrated products should not be mixed directly unless compatibility has been confirmed.
Q12. Is ALCA SOLUTION the same as a condensate neutralizing amine?
No. ALCA SOLUTION is intended primarily for boiler water alkalinity control. Neutralizing amines are used mainly to control pH and carbonic acid corrosion in steam and condensate systems.
Q13. What is the recommended dosage?
Dosage depends on the chemical concentration, boiler water analysis and operating requirements. A product-specific dosage cannot be established without these details.
RXSOL Boiler Water Treatment Chemical Supplier in India, UAE and Oman
RXSOL supplies marine and industrial boiler water treatment chemicals for shipping companies, shipyards, power plants and industrial maintenance operations.
India: Mumbai, Kandla, Mundra, Hazira, Kolkata, Haldia, Chennai, Ennore, Visakhapatnam, Kakinada, Paradip and other industrial centres.
United Arab Emirates: Dubai, Fujairah, Sharjah, Abu Dhabi, Jebel Ali and Ruwais.
Oman: Muscat, Sohar, Salalah and Duqm.
Other Markets: Qatar, Saudi Arabia and international shipping destinations, subject to availability and delivery arrangements.
RXSOL Alkalinity Control – Manufacturer, Supplier and Exporter
RXSOL provides boiler water treatment chemicals for marine auxiliary boilers, industrial steam generators and water treatment service providers.
Our boiler treatment portfolio includes alkalinity control agents, phosphate treatments, oxygen scavengers, sludge conditioners and condensate treatment chemicals.
For product specifications, dosing recommendations, SDS, COA, packing and bulk supply enquiries, contact the RXSOL technical sales team.
Product Details
|
Product Element |
Product Content |
|---|---|
|
Product Title |
Alkalinity Control Boiler Water Treatment Chemical – RXSOL |
|
Product Description |
RXSOL Alkalinity Control boiler water treatment chemical for pH adjustment, corrosion control and alkalinity management in marine and industrial boilers. |
|
Product Keyword |
Alkalinity Control Boiler Water Treatment Chemical |
|
Product SET |
|
|
Product Keywords |
Boiler Water Alkalinity Booster, Boiler pH Controller, Marine Boiler Water Treatment, Boiler Corrosion Inhibitor, Hydroxide Alkalinity Control, Industrial Boiler Treatment Chemical |
|
Suggested Field |
RXSOL Alkalinity Control – Marine & Industrial Boiler Water Treatment Chemical |
Technical note: The product code and actual composition have not been provided. Before publishing this as a certified RXSOL technical data sheet, confirm the formulation, concentration, pH, specific gravity, approved operating pressure range and boiler water control limits.
Alkalinity control makes sludge in soft form, which can be easily blown down from bottom side of BOILER.
Other valuable Boiler Water Treatment Chemical product :
| RXSOL-50-5020-025 | Boiler Water Treatment Auto |
| RXSOL-40-4091-025 | Scale and Corrosion Inhibitor for Cooling Water |
| RXSOL-40-4009-025 | MICRO BIOCIDE Cooling Water |
| RXSOL-50-5002-025 | Alkalinity Control |
| RXSOL-40-2000-025 | RXSOL 2000 corrosion inhibitor |
| RXSOL-40-4009-025 | MICRO BIOCIDE Cooling Water |
| RXSOL-50-5021-025 | Hardness Control Liquid |
Product Description & Chemical Profile
RXSOL Alkalinity Control – Boiler Water Treatment Chemical
Boiler Water pH Controller | Alkalinity Booster | Boiler Corrosion Prevention | Marine & Industrial Boiler Treatment
Brand: RXSOL – RX Marine International
Product Name: RXSOL Alkalinity Control
Product Category: Boiler Water Treatment Chemicals
Chemical Type: Alkaline Boiler Water Conditioning Agent
Applications: Marine Boilers, Auxiliary Boilers, Industrial Steam Boilers and Boiler Feedwater Systems
Product Description
RXSOL Alkalinity Control is a concentrated alkaline boiler water treatment chemical designed to maintain the required alkalinity and pH in marine and industrial boiler systems.
Proper boiler water alkalinity is essential for controlling corrosion, maintaining effective phosphate treatment and supporting efficient steam generation.
During boiler operation, variations in feedwater quality, condensate return and makeup water composition can cause fluctuations in boiler water alkalinity. Insufficient alkalinity may increase the risk of corrosion, while excessive alkalinity can contribute to foaming, carryover and caustic-related damage.
RXSOL Alkalinity Control is intended to maintain the required alkaline conditions within the boiler, helping protect internal metal surfaces and supporting reliable boiler operation.
The product is suitable for use as part of a comprehensive boiler water treatment program incorporating oxygen scavengers, phosphate treatment, sludge conditioners and routine water analysis.
Boiler Water Treatment Chemicals Concentrated liquid alkaline product for corrosion and Calcium scale control in boilers. Very usefull Concentrated Alkaline Liquid For Maintaining Ph - To adjust alkalinity.
Suitable for Low-pressure boiler systems (0-32 bar) , medium-pressure steam propulsion vessels (32-60 bar). And also suitable to used for high pressure steam generating systems (60-84 bar).
Mechanism : It converts calcium hardness into soft, non-adherent sludge that is easily removed by blowdown.
Need pricing, bulk volume, or vessel delivery today?
Send us your required quantity, delivery location, or vessel IMO number. Our technical marine supply team replies within 1 hour.